MODEL | INPUT | OUTPUT | |||||
---|---|---|---|---|---|---|---|
SR. | TYPE OF SSR | CURRENT/VOLTAGE | VOLTAGE | CURRENT AMP AT 20°C | CURRENT HEATSINK AT 55°C | FUSING CURREN l2t | TYPE OF HEATSINK |
1 | SP11PAC25 | 4-20mA/0-10VDC | 230/440VAC | 25Amp | 14Amp | 312A2S | I-68 |
2 | SP11PAC40 | 4-20mA/0-10VDC | 230/440VAC | 40Amp | 18Amp | 800A2S | B-77 |
3 | SP11PAC50 | 4-20mA/0-10VDC | 230/440VAC | 50Amp | 25Amp | 3000A2S | D-77 |
4 | SP11PAC75 | 4-20mA/0-10VDC | 230/440VAC | 75Amp | 37Amp | 3200A2S | K-9 |
5 | SP11PAC90 | 4-20mA/0-10VDC | 230/440VAC | 90Amp | 45Amp | 7200A2S | E-100 |
6 | SP11PAC150 | 4-20mA/0-10VDC | 230/440VAC | 150Amp | 75Amp | 15000A2S | E-100 |
7 | 100PAC25 | 4-20mA/0-10VDC | 230/440VAC | 25Amp | 14Amp | 312A2S | I-68 |
8 | 100PAC40 | 4-20mA/0-10VDC | 230/440VAC | 40Amp | 18Amp | 80A2S | B-77 |
9 | 100PAC50 | 4-20mA/0-10VDC | 230/440VAC | 50Amp | 25Amp | 3000A2S | D-77 |
10 | 100PAC75 | 4-20mA/0-10VDC | 230/440VAC | 75Amp | 37Amp | 3200A2S | K-9 |
11 | 100PAC90 | 4-20mA/0-10VDC | 230/440VAC | 90Amp | 45Amp | 7200A2S | E-100 |
12 | 100PAC150 | 4-20mA/0-10VDC | 230/440VAC | 150Amp | 75Amp | 15000A2S | E-100 |
13 | KC25PAC | 4-20mA/0-10VDC | 230/440VAC | 25Amp | 14Amp | 312A2S | K-2 |
14 | KC40PAC | 4-20mA/0-10VDC | 230/440VAC | 40Amp | 18Amp | 800A2S | K-2 |
15 | KC50PAC | 4-20mA/0-10VDC | 230/440VAC | 50Amp | 25Amp | 3000A2S | K-5 |
16 | KC75PAC | 4-20mA/0-10VDC | 230/440VAC | 75Amp | 37Amp | 3200A2S | K-9 |
17 | KC90PAC | 4-20mA/0-10VDC | 230/440VAC | 90Amp | 45Amp | 7200A2S | K-9 |
18 | 05 3PH PAC44 25 420 | 4-20mA/0-10VDC | 230/440VAC | 25Amp | 14Amp | 312A2S | C-105 |
19 | 05 3PH PAC44 40 420 | 4-20mA/0-10VDC | 230/440VAC | 40Amp | 18Amp | 800A2S | C-105 |
20 | 05 3PH PAC44 50 420 | 4-20mA/0-10VDC | 230/440VAC | 50Amp | 25Amp | 3000A2S | G-105 |
21 | 05 3PH PAC44 75 420 | 4-20mA/0-10VDC | 230/440VAC | 75Amp | 37Amp | 3200A2S | E-100 |
22 | 05 3PH PAC 44 90 420 | 4-20mA/0-10VDC | 230/440VAC | 90Amp | 45Amp | 7200A2S | E-100 |
SR. | DESCRIPTION | UNIT | BACK TO BACK SCR |
---|---|---|---|
1 | Operational Voltage Range | Vrms | 0-230VAC / 0-440VAC |
2 | Peak Inverse Voltage | Vpk | 800Vpk / 1200Vpk |
3 | Rated Operational Current at 20C° | It | 25A|40A|50A|75A |90A |150A |
4 | Rated Operational Current at 55C° | It | 14A|18A|25A|37A |45A |75A |
5 | Minimum Holding Current | Ih | 175/250/275mA |
6 | Rated Peak with Stand Current | Itms | 320/775/1200A |
7 | Max. Load Integral i2dt (t=10ms) | i2t | 312/800/3000/3200/7200/15000A2S |
8 | Voltage Drop in ON-State | Vtm | 3V to 4V |
9 | Isolation Voltage | KV | 4KV |