DC to AC/AC to AC (Three Phase)

DC to AC/AC to AC (Three Phase)

DC TO AC / AC TO AC (Three Phase)Specification:-

MODELINPUTOUTPUT
SR.TYPE OF SSRVOLTAGECURRENTVOLTAGECURRENT AMP AT 20°CCURRENT HEATSINK AT 55°CFUSING CURREN l2tTYPE OF HEATSINK
105 3PH DA 48 25 005-32VDC4-16mA24-480VAC25Amp14Amp312A2SC-105
205 3PH DA 48 40 005-32VDC4-16mA24-480VAC40Amp18Amp800A2SC-105
305 3PH DA 48 50 005-32VDC4-16mA24-480VAC50Amp25Amp3000A2SG-105
405 3PH DA 48 75 005-32VDC4-16mA24-480VAC75Amp37Amp3200A2SE-100
505 3PH DA 48 90 005-32VDC4-16mA24-480VAC90Amp45Amp7200A2SE-100
605 3PH AA 48 25 285-32VDC4-16mA24-480VAC25Amp14Amp312A2SC-105
705 3PH AA 48 40 285-32VDC4-16mA24-480VAC40Amp18Amp800A2SC-105
805 3PH AA 48 50 285-32VDC4-16mA24-480VAC50Amp25Amp3000A2SG-105
905 3PH AA 48 75 285-32VDC4-16mA24-480VAC75Amp37Amp3200A2SE-100
1005 3PH AA 48 90 285-32VDC4-16mA24-480VAC90Amp45Amp7200A2SE-100

Input Technical Data:-

Output Technical Data:-

SR. DESCRIPTION UNIT BACK TO BACK SCR
1 Operational Voltage Range Vrms 24-480VAC
2 Peak Inverse Voltage Vpk 1200Vpk
3 Rated Operational Current at 20C° It 25A | 40A | 50A | 75A | 90A
4 Rated Operational Current at 55C° It 14A | 18A | 25A | 37A | 45A
5 Minimum Holding Current Ih 175/275mA
6 Rated Peak with Stand Current Itms 320/775/1200A
7 Max. Load Integral i2dt (t=10ms) i2t 312/800/3000/3200/7200A2S
8 Voltage Drop in ON-State Vtm 1.3V
9 Isolation Voltage KV 4KV
10 Frequency Range Hz 45-65Hz
11 Max. OFF State Leakage Current mA <2mA Rms
12 Max. Zero Voltage Turn ON Vpk 15
13 3PHASE Motor HP kW 3HP | 7.5HP | 10HP 2.25kW | 5.5kW | 7.5kW

Sailent Features:-

Applications:-

Advantages:-

Precaution:-