DC to AC (Single Phase)
DC to AC (Single Phase) Specification:-
MODEL | INPUT | OUTPUT | ||||||
---|---|---|---|---|---|---|---|---|
SR. | TYPE OF SSR | VOLTAGE | CURRENT | VOLTAGE | CURRENT AMP AT 20°C | CURRENT HEATSINK AT 55°C | FUSING CURREN l2t | TYPE OF HEATSINK |
1 | SP11ZDA16 | 4-32VDC | 4-16mA | 24-480VAC | 16Amp | 10Amp | 312A2S | A-68 |
2 | SP11ZDA25 | 4-32VDC | 4-16mA | 24-480VAC | 25Amp | 14Amp | 312A2S | I-68 |
3 | SP11ZDA40 | 4-32VDC | 4-16mA | 24-480VAC | 50Amp | 25Amp | 3000A2S | D-77 |
4 | SP11ZDA50 | 4-32VDC | 4-16mA | 24-480VAC | 50Amp | 25Amp | 3000A2S | D-77 |
5 | SP11ZDA75 | 4-32VDC | 4-16mA | 24-480VAC | 75Amp | 37Amp | 3200A2S | K-9 |
6 | SP11ZDA90 | 4-32VDC | 4-16mA | 24-480VAC | 90Amp | 45Amp | 7200A2S | E-100 |
7 | SP11ZDA150 | 4-32VDC | 4-16mA | 24-480VAC | 150Amp | 75Amp | 15000A2S | E-100 |
8 | 100ZDA16 | 4-32VDC | 4-16mA | 24-480VAC | 150Amp | 75Amp | 15000A2S | E-100 |
9 | SP11ZDA150 | 4-32VDC | 4-16mA | 24-480VAC | 150Amp | 75Amp | 15000A2S | E-100 |
10 | SP11ZDA150 | 4-32VDC | 4-16mA | 24-480VAC | 150Amp | 75Amp | 15000A2S | E-100 |
11 | SP11ZDA150 | 4-32VDC | 4-16mA | 24-480VAC | 150Amp | 75Amp | 15000A2S | E-100 |
12 | SP11ZDA150 | 4-32VDC | 4-16mA | 24-480VAC | 150Amp | 75Amp | 15000A2S | E-100 |
13 | SP11ZDA150 | 4-32VDC | 4-16mA | 24-480VAC | 150Amp | 75Amp | 15000A2S | E-100 |
14 | SP11ZDA150 | 4-32VDC | 4-16mA | 24-480VAC | 150Amp | 75Amp | 15000A2S | E-100 |
15 | KC16ZDA | 4-32VDC | 4-16mA | 24-480VAC | 16Amp | 10Amp | 312A2S | K-1 |
16 | KC25ZDA | 4-32VDC | 4-16mA | 24-480VAC | 25Amp | 14Amp | 312A2S | K-2 |
17 | KC40ZDA | 4-32VDC | 4-16mA | 24-480VAC | 40Amp | 18Amp | 800A2S | K-2 |
18 | KC50ZDA | 4-32VDC | 4-16mA | 24-480VAC | 50Amp | 25Amp | 3000A2S | K-5 |
19 | KC75ZDA | 4-32VDC | 4-16mA | 24-480VAC | 75Amp | 37Amp | 3200A2S | K-9 |
20 | KC90ZDA | 4-32VDC | 4-16mA | 24-480VAC | 90Amp | 45Amp | 7200A2S | K-9 |
21 | 08 DA 48 25 00 | 4-32VDC | 4-16mA | 24-480VAC | 25Amp | 12Amp | 312A2S | H-30 |
22 | 07 DA 48 08 00 | 4-32VDC | 4-16mA | 24-480VAC | 8Amp | 4Amp | 312A2S | J-15 |
Input Technical Data:-
Output Technical Data:-
- Input Control Supply Voltage 4-32VDC
- Input Control Supply Current 4-16mA
SR. | DESCRIPTION | UNIT | ALTERNISTOR TRIAC | BACK TO BACK SCR |
---|---|---|---|---|
1 | Operational Voltage Range | Vrms | 24-480VAC | 24-480VAC |
2 | Peak Inverse Voltage | Vpk | 800Vpk | 1200Vpk |
3 | Rated Operational Current at 20C° | It | 8A | 16A | 25A | 40A | 50A | 75A | 90A | 150A |
4 | Rated Operational Current at 55C | It | 4A | 10A | 14A | 18A | 25A | 37A | 45A | 75A |
5 | Minimum Holding Current | Ih | 175mA | 250/275mA |
6 | Rated Peak with Stand Current | Itms | 320A | 775/1200/1700A |
7 | Max. Load Integral i2dt (t=10ms) | i2t | 312/800A2S | 3000/3200/7200/15000A2S |
8 | Voltage Drop in ON-State | Vtm | 1.2V | 1.2V |
9 | Isolation Voltage | KV | 4KV | 4KV |
Sailent Features:-
- True Zero Cross Over
- Virtually Free From EMI/RFI
- Input LED Green Indication
- Output to Body 4KV Isolation
- Noiseless Without Chattering and Fast Switching
- Inbuilt Snubber
- Heatsink + Dinrail Mounting (35mm)
- Reverse Polarity Protection
- Output N/O Configurtion
- Random Type SSR (Optionally)
Applications:-
- Temp. Controller in Ovens & Furnace
- Solid and Liquid Packaging Equipments
- Forward-Reverse Of Motor in CNC Machines
- Controlling of Infrared Heaters
- Plastic Processing, Injection Moulding, Blow Moulding & Extrusion Machineries
- Printing machinery
- Texturising Machinery
- Medical Equipments
- ON/OFF Motor Control
- Hot Runner Systems
Advantages:-
- Contac Less Logic Relay With Switching Performed By Semiconductor Device
- True Zero Voltage Turn ON/OFF
- Input Output Isolation 4KV
- High Speed & High Frequency Switching
- Longer Life Dus To Infinite Number Of Switching
Precaution:-
- For Load Current More Than 3Amp External heatsink is Must
- Apply Heatsink Pest on The Base Plate Of The Before Mounting it External Heatsink
- Fast Acting Fuse Require For Protection SSR
- SSR Rating Should Be More or Equal to Maximum Jerk Current Of Load
- Do Not Check SSR Meter Or Continuity tester Otherwise it Will Always Shows OPEN