Phase Angle Controller by Pot Specification:-

MODEL INPUT OUTPUT
SR. TYPE OF SSR VOLTAGE VOLTAGE CURRENT AMP AT 20°C CURRENT HEATSINK AT 55°C FUSING CURREN l2t TYPE OF HEATSINK
1 SP11POT25FULL 100K ohm 0-230VAC 25Amp 14Amp 312A2S I-68
2 SP11POT50FULL 100K ohm 0-230VAC 50Amp 25Amp 3000A2S D-77
3 SP11POT90FULL 100K ohm 0-230VAC 90Amp 45Amp 7200A2S E-100
4 SP11POT150FULL 100K ohm 0-230VAC 150Amp 75Amp 15000A2S E-100
5 100POT25FULL 100K ohm 0-230VAC 25Amp 14Amp 312A2S I-68
6 100POT50FULL 100K ohm 0-230VAC 50Amp 25Amp 3000A2S D-77
7 100POT90FULL 100K ohm 0-230VAC 90Amp 45Amp 7200A2S E-100
8 100POT150FULL 100K ohm 0-230VAC 150Amp 75Amp 15000A2S E-100
9 SP11POT25HALF 100K ohm 0-230VAC 25Amp 14Amp 312A2S I-68

Input Technical Data:-

Output Technical Data:-

SR. DESCRIPTION UNIT BACK TO BACK SCR
1 Operational Voltage Range Vrms 0-230VAC
2 Peak Inverse Voltage Vpk 800Vpk / 1200Vpk
3 Rated Operational Current at 20C° It 25A|50A|90A|150A
4 Rated Operational Current at 55C° It 14A|25A|45A |75A
5 Minimum Holding Current Ih 175/250/275mA
6 Rated Peak with Stand Current Itms 320/775/1200/1700A
7 Max. Load Integral i2dt (t=10ms) i2t 312/3000/7200/15000A2S
8 Voltage Drop in ON-State Vtm 1.2V
9 Isolation Voltage KV 4KV

Applications:-

Sailent Features:-